• fib Model Code for Concrete Structures (2020)

    +

  • fib President Stephen Foster

    fib President Stephen Foster

    fib President 2023-2024

  • The International Federation for Structural Concrete

    The International Federation for Structural Concrete

    A Bridge between Research and Practice



    The knowledge developped and shared by the fib (fib Bulletins, fib events, fib workshops, fib courses, etc.) is entirely the result of the volunteer work provided by the fib members.

    +

Limit states of cracking in beam-and-block floor systems using pretensioned ribs

R. S. Camposinhos, Instituto Politecnico do Porto, Portugal
A. Serra Neves, University of Porto, Portugal

Beam-and-block floor systems using pretensioned ribs enable very efficient industrialised production. By ensuring that the ribs are produced under a strict quality assurance programme and that they are safely transported, assembled and properly detailed, an equally monolithic structural performance is achieved. However, calculation methods to control cracking in these structural elements must ensure the durability according to the surrounding environment's severity and predefined exposure classes. The design of beam-and-block floor systems is particularly affected by serviceability limit states. This fact is closely linked to the verification conditions for crack control. Therefore, new design models have been developed to take into account the peculiarities and characteristics of these floor systems. The aim is to find practical and effective crack-control methods for composite beam-and-block floor systems with pretensioned ribs or beams. The verification of the limit state of crack widths has so far been disregarded in the design of this type of lightweight slab. In fact, the current procedure is simply to compare the tensile stress in the lower fibre of the beams with the characteristic strength of the rib's concrete. This paper presents a method to assess crack control. The procedure implies the quantification of a limit bending moment depending on the physical and geometric characteristics of the sections. Simplified calculation methods and verification rules are presented, which allow the establishment of tables and design charts for the indirect verification of this limit state through bar size and spacing limits. 

fib postal address

Ch. du Barrage, Station 18
CH-1015 Lausanne
Switzerland

Contact

p : +41 21 693 27 47
f : +41 21 693 62 45
e : info@fib-international.org
w : www.fib-international.org

Follow fib

Subscribe our newsletter

News

Follow us on
           

Join the fib

Join the fib