• Latest news

    Latest news

  • Latest news

    Latest news

Structural Concrete, Vol. 9, no. 4, December 2008

Fatigue life of short-span reinforced concrete railway bridges

M. Pimentel, Laboratory for Concrete Technology and Structural Behaviour (LABEST), University of Porto, Portugal
E. Brühwiler, School of Architecture, Civil and Environmental Engineering, École Polytechnique Fédérale de Lausanne (EPFL), Switzerland 
J. Figueiras, Laboratory for Concrete Technology and Structural Behaviour (LABEST), University of Porto, Portugal

In this paper a parametric study on the fatigue life of short-span reinforced concrete railway bridges is presented. Only reinforcement steel fatigue damage is considered. The objective of this work is to assess the factors that may have a decisive influence on reinforcement fatigue life, to evaluate the consequences of the increasing traffic loads and to identify the research needs so as to allow more accurate fatigue examinations of existing bridges under more demanding traffic conditions. It is concluded that reinforcement fatigue life is mainly governed by the existence of heavy traffic (freight trains) and that it is highly sensitive both to the axle loads increase and to the accuracy in the reinforcement stress range calculation. It is also shown that the current analysis procedures may suffice for economic design of new bridges, whereas in the case of existing bridges more elaborate analysis procedures may be necessary to prove fatigue safety.

 

Structural Concrete, Vol. 9, no. 4, December 2008

Concrete coating for marine pipelines

M. Braestrup, Rambøll, Denmark 

A significant, but fairly unnoticed, use of structural concrete is as weight coating to ensure sufficient negative buoyancy, as well as mechanical protection, of submarine pipelines, primarily for the transportation of oil and gas. After a brief introduction to marine pipeline technology the paper describes the design, application and testing of concrete coatings. Finally, the enhancement of pipeline installation stresses due to the greater flexibility of the uncoated construction joints is discussed. 

Structural Concrete, Vol. 9, no. 4, December 2008

Post-heating bond behaviour between lightweight fibrous concrete and steel

R.H. Haddad, Dept. of Civil Engineering, Jordan University of Science and Technology, Irbid, Jordan
Z.G. Al-Kofahi, Dept. of Civil Engineering, Jordan University of Science and Technology, Irbid, Jordan


The post-heating bond behaviour between fibre reinforced lightweight aggregate concrete (LWAC) and 20 mm-diameter steel bars was experimentally investigated using a modified type of pullout specimen. These were cast using volcanic tuff aggregate concrete with and without hooked steel, brass-coated steel, and a mixture of both types of fibres at a volumetric fraction of 2%, before being water cured for 28 days and subjected to high temperatures, ranging from 300 to 700 C. Standard cubes were also cast, cured and heat-treated under similar conditions before being tested to evaluate compressive and splitting strengths. Duplicate specimens, from various mixtures, were cured in water for a similar period and used as controls. The post-heating cracking pattern and extent were evaluated, and residual strengths and bond behaviour determined and described before and after heating then cooling. The results showed marked reductions in residual bond, compressive and splitting strengths of plain and fibre reinforced LWAC being exposed to high temperatures. Pullout specimens prepared with fibres attained higher residual bond strength and bond ductility after exposure to high temperatures than those of plain ones. The contribution of hooked steel fibres (at volumetric fractions of 1 or 2%) to salvaging bond was over the entire temperature spectrum, while that of brass-coated steel fibres was limited to the lower range of that spectrum (from 300 to 500 C). The findings of the present study confirmed the benefit of using lightweight aggregate in reinforced concrete structures as it contributes to maintaining higher post-heating residual bond strength than that of conventional concrete.

Structural Concrete, Vol. 9, no. 3, September 2008

Analysis and cost optimisation of prestressed concrete joists in beam-block floors

Vanessa Cristina de Castilho, Universidade Federal de Uberlandia, Brazil
Maria Cristina Vidigal de Lima, Universidade Federal de Uberlandia, Brazil


The overall production costs of precast concrete elements are important to quantify. Analyses of the constructive stages of these elements, however, may more realistically lead to a function representing production, transport, assembly and casting costs. This article investigates the cost minimisation problems of joists in beam-block floors using a heuristic method known as genetic algorithm (GA) and a conventional method known as generalised reduced gradient (GRG2). The continuous variables considered in the problem were prestressed reinforcements in the three levels, distance between reinforcements, concrete layer strength, distance between joists, concrete layer thickness and degree of redistribution of the continuous slabs' negative moments. Based on the results, the heuristic method was found to be effective in identifying the solution for precast element cost minimisation problems. The performance of the cost function vis-à-vis market alterations was evaluated considering the influence of concrete, reinforcement and labour prices. 

Structural Concrete, Vol. 9, no. 3, September 2008

Load carrying capacity of cracked concrete railway sleepers

Håkan Thun, Lulå University of Technology, Sweden
Sofia Utsi, Luleå University of Technology, Sweden
Lennart Elfgren, Luleå University of Technology, Sweden

The load carrying capacity of damaged prestressed concrete railway sleepers has been investigated in order to obtain information about how the cracking influences the remaining load carrying capacity compared with an uncracked sleeper. The following tests have been performed: bending capacity of the midsection, the rail section, horizontal load capacity of the fastener, control of the concrete properties and fatigue capacity in bending of the rail section. A visual inspection and classfication of the damages are also presented. The test results have been compared with calculations according to the Swedish railway code for sleepers and show that railway sleepers are quite robust. Small cracks do not seem to influence the load carrying capacity and it is first when the cracking is very severe that the load carrying capacity is reduced significantly.

Structural Concrete, Vol. 9, no. 3, September 2008

Effect of grout proportions on strength of two-stage concrete

Hakim S. Abdelgader, Department of Civil Engineering, Al-Fateh University, Tripoli, Libya 
Abdurrahman A. Elgalhud, El-Mergib University, Al-Khoms, Libya


The objective of this paper was to study the manufacture of suitable grouts for two-stage (pre-placed aggregate) concrete using different admixtures to improve flowability of grout and hence the strength of two-stage concrete. The hypothesis of two-stage concrete is different from conventional concrete, because the particle-to-particle contact of coarse aggregate shrinkage is lower than that of normal concrete. The most important aspect of two-stage concrete strength still remains unclear. The strength of two-stage (pre-placed aggregate) concrete has been described in different ways, by experiment or theory. As no reliable data are available showing the strength of two-stage (pre-placed aggregate) concrete, it was necessary to investigate its strength at different mixes. This paper deals with the effect of different types of admixture on the concrete strength of two-stage (pre-placed aggregate) concrete. The paper also presents experimental results of pre-placed crushed aggregate concrete using 36 different grout mixture proportions. A total of 360 standard concrete cylinders were tested in unconfined compression and tensile strength at 28 days. On the basis of these results, a relationship between the tensile strength and compressive strength of two-stage (pre-placed aggregate) concrete has been statistically derived. 